FMA-CBL (Cables)#
FMA-FC-150/60-V1: Flex Cable for MIPI CSI-2 Connections#
FSA to FPA for MIPI CSI-2 connections (mandatory)
Extension through “daisy-chaining” possible (maximum length is sensor and setup depending)
Rigid-flex design (connectors on rigid PCBs)
Note: Don’t use for any other connections than for MIPI CSI-2. Might lead to signal degradation and even damage!
Flex Cable Connectors
FSA Side: Hirose DF40C-60DS-0.4V
FPA Side: Hirose DF40C-60DP-0.4V
Pin Assignment: Pin 1 to Pin 1
Mechanical Drawing
Top Side
Bottom Side
FMA-FC-150/60-LVDS-V1: Flex Cable for Sub-LVDS, SLVS and SLVS-EC Connections#
FSA to FPA for Sub-LVDS, SLVS and SLVS-EC connections (mandatory)
Extension through “daisy-chaining” possible (maximum length is sensor and setup depending)
Rigid-flex design (connectors on rigid PCBs)
Note: Don’t use for MIPI CSI-2 connections. Might lead to signal degradation and even damage!
Flex Cable Connectors
FSA Side: Hirose DF40C-60DS-0.4V
FPA Side: Hirose DF40C-60DP-0.4V
Pin Assignment: Pin 1 to Pin 1
Mechanical Drawing and Pinout
Top Side
Bottom Side