NVIDIA Jetson AGX Thor Devkits#

Introduction#

This guide provides detailed instructions for connecting FSM:GO modules to the NVIDIA Jetson AGX Thor Developer Kit through the Lattice Holoscan Sensor Bridge, using the FPA-4.A/AGX-V1A adapter.

Pre-assembly Information#

The FSM:GO sensor module is typically pre-assembled with a standard lens mount and the lens of your choice.

1. Add an M12 lens mount (optional)#

Prior to assembling the FSM to the FPA-4.A/AGX-V1A, screw an optional M12 lens mount to the FSM.

Fitting screws are provided with the lens mount. If assembling a third-party mount, refer to the technical drawings for the specific module to confirm hole diameters and select the appropriate screws.

../../../_images/Connect-1s1.svg

Note

The FSM:GO sensor module is shipped pre-assembled with the default lens mount and lens.

If change is needed, refer to the M12 Lens Kit User Guide for detailed instructions on changing the mount.

Note

Always ensure that the lens mount is securely fastened to prevent any movement during operation.

Assembly Instructions#

Connecting the FSM:GO module to the Nvidia Jetson AGX Thor via the FPA-4.A/AGX interface can be achieved through a few different setups, each suited for different application needs. Below are detailed instructions for each cabling solution.

Connecting the FSM:GO Module to Holoscan Bridge#

Caution

Ensure the power supply is off while making connections to avoid electrical issues.

Requirements

Note

For longer cable length requirements, the SFP+ DAC cable can be replaced with a fiber optic connection: two 10G SFP+ optical transceivers (one in the sensor bridge’s SFP+ 0 port, one in the QSA adapter) and a matching fiber patch cable. All other steps remain the same.

Step 1: Connecting the Flex Cable to the FSM:GO Module#

../../../_images/Thor_1.jpg

Image Module and Flex Cable#

  1. Orientation Check: Identify pin-1 on both the FSM:GO module and the FMA-FC-150/60 flex cable. This is crucial to ensure correct alignment and functionality.

  2. Connection: Align the 60-pin PixelMate connectors on the FSM:GO module and the flex cable. Carefully press them together until they are securely connected.

../../../_images/Connect-19s.svg

Connecting the flex cable to the FSM:GO module.#


Step 2: Connecting the Flex Cable to the FPA-4.A/AGX-V1A#

../../../_images/Thor_3.jpg

FSM:GO module and flex cable with the FPA-4.A/AGX-V1A#

  1. Connection: Attach the other end of the FMA-FC-150/60 flex cable to the J5 connector on the FPA-4.A/AGX-V1A.

../../../_images/Thor_4.jpg

Connecting the flex cable to the FPA-4.A/AGX-V1A.#

Note

Before connecting, verify correct orientation to avoid permanent damage. The connectors are correctly oriented when the “1” markings on their faces, which indicate pin-1 on each connector, mirror one another.

Step 3: Connecting the FPA-4.A/AGX-V1A to the Lattice Holoscan Sensor Bridge#

../../../_images/Thor_5.jpg

Current step assembly (FSM:GO Module+Flex Cable+FPA-4.A/AGX-V1A and the Lattice Holoscan Bridge)#

  1. Connection: Mount the FPA-4.A/AGX-V1A adapter to the Camera Connector on the Holoscan Sensor Bridge, pressing evenly until it’s fully seated.

../../../_images/Thor_6.jpg

FPA-4.A/AGX-V1A mounted on the Lattice Holoscan Sensor Bridge#

Connecting two FSM:GO Modules To The Holoscan Sensor Bridge#

When attempting to connect two FSM:GO Modules to the Holoscan Sensor Bridge at the same time, follow the procedures listed above for both modules, using the J5 connector for the first, and the J6 connector for the second connection.

../../../_images/2xFSM_Connection.jpg

Two FSM:GO Modules Connected to the Holoscan Sensor Bridge#

Connecting The Holoscan Bridge to NVIDIA Jetson AGX Thor#

Scenario 1: Adding the SFP+ DAC Cable and Power Connection#

  1. SFP+ Cable Connection: Connect the Holoscan Sensor Bridge’s SFP+ 0 port to the AGX Thor Devkit via SFP+ DAC cable (with QSFP adapter) to establish data transmission pathways.

  2. Power Connection: Attach the USB-C power connector to the Lattice Holoscan Sensor Bridge.

  3. Powering on: Once everything is connected, power AGX Thor on.

../../../_images/SFP%2BQSFP_cable.jpg

SFP+ Cable Connector with QSFP Adapter#

../../../_images/Thor_8.jpg

Adding the SFP+ DAC cable and power connection.#

../../../_images/Single_QSFP_Connector.jpg

QSFP Adapter connector on AGX Thor#

Scenario 2: Adding the QSFP to 4x SFP+ Breakout Cable and Power Connection#

  1. QSFP Breakout Cable Connection: In order to establish data transmission pathways, connect the QSFP end of the breakout cable to the AGX Thor Devkit, then connect the branch labeled 1 to the SFP+ 0 port on the Holoscan Sensor Bridge. Leave the other branches unconnected.

  2. Power Connection: Attach the USB-C power connector to the Lattice Holoscan Sensor Bridge.

  3. Powering on: Once everything is connected, power AGX Thor on.

../../../_images/SFP_Breakout_Cable.png

10Gtek QSFP to 4x SFP+ breakout cable.#

../../../_images/Thor_7.jpg

Adding the QSFP Breakout cable and power connection.#

Software Installation#

Note

The FRAMOS drivers for Jetson AGX Thor are validated with JetPack 7.2.1. Flash the AGX Thor Developer Kit with this release before installing the drivers.

To set up your Framos camera module on your NVIDIA Jetson AGX Thor devkit, all required drivers and installation instructions are provided in the official Framos GitHub repositories:

Framos NVIDIA Jetson Drivers

This repository contains:

  • Installation scripts to simplify setup

  • Release notes

  • Configuration examples for different use cases

For the most up-to-date guidance and sensor compatibility, always refer to the repositories above.